Efficient delivery outlet DOP leak detection method and detection method
DOP tank efficient delivery outlet preferred Ling Jie Guangzhou Li, consulting engineering 13423677201

the efficient delivery outlet itself and its installation is obvious leakage, must be tested on the following in the field: filter; internal filter and frame connection filter; between the gasket and the filter group support frame filter framework; between the supporting frame and wall or ceiling.
DOP test materials, equipment: dust source (PAO solvent), TDA-6C aerosol generator, aerosol photometer.
The aerosol generator I use the ATI TDA-6C. handheld Laskin nozzle type aerosol generator, which directly use the air without the need of compressed gas as power. In the 20Pa working pressure, airflow velocity is 50~2025f3/min, can produce 10~100ug/mL concentration polydisperse submicron oil dust aerosol. Aerosol photometric meter used for ATI 2H type photometer, dynamic measurement range is 0.00005~120ug/L, the sampling flow rate is 1F3/min (28.3L/min).
On the measured HEPA upstream side into the PAO aerosol
HVAC system for the HEPA, as the concentration of the aerosol reach HEPA always uniform, can be imported directly from the negative side of the aerosol system of the wind turbine, such as from the introduction of the wind pipe, it should be in the range HEPA at least 10 times the air pipe diameter is introduced, and minimize the corner (America environmental science and Technology Institute). Under normal circumstances, keep the upstream aerosol concentration is reached, and the concentration fluctuation in a certain range. For the laminar flow hood, ultra clean table HEPA, aerosol direct from the negative side of the system fan.
Aerosol photometer initialization, set 100%, 0% reference standard value
In accordance with the aerosol photometer and operation requirements for initialization, set the alarm value. The UPSTREAM sample tube is connected with the upper sampling port, measuring ring sol concentration. According to the regulation of the aerosol concentration of aerosol generator operating requirements, so that the upstream aerosol concentration reaches 10~20ug/mL.
Diffuser plate scanning leak off HEPA, the filter, filter and the border between the frame and the frame, and between the frame and the static pressure box seal between the scanning. The scan sampling head from the filter surface about 1 inches (about 2.54cm), the scanning speed is not more than 5cm/s. Scanning according to the straight back and forth reciprocally, between the lines shall overlap. The detection process, if the alarm sound (i.e.%LEAKAGE (leakage) more than 0.01%), indicate that there is a leak. Leakage after the silica gel plugging or fastening and scan again inspection. Check a filter is about 5min, in the testing process, often should confirm the upstream aerosol concentration, attention in the detection process should take protective mask and protective goggles.
Technical consultation: 13423677201

elivery outlet: http://www.linjec.com
Related: efficient delivery outlet efficient delivery outlet leakage efficient delivery outlet DOP detection method DOP efficient delivery outlet DOP efficient delivery outlet for detection of DOP efficient delivery outlet - manufacturer of liquid tank type efficient delivery outlet tank sealing efficient delivery outlet