Brief introduction of HEPA filtering technology
Date:2021-04-20   Hits:6248
Brief introduction of HEPA filtering technology
The HEPA filter cooperation, consultation Li Gong 15914315027, soul purification, quality of the world
The HEPA filter is used in the cleanrooms in many different industries, including semiconductor, dispensing medical equipment, nuclear, and biotechnology. The main function of the HEPA filter will provide clean air on cleanroom. The HEPA filter is constructed to filter media paper many pleated layers; this design to prevent particles freely through the filter when they become trapped and stick filter fiber (Figure 1). There are four mechanisms at work: captured by the strain, impaction, interception, and diffusion (Fig. 2). Straining/sieving is defined and when the particles are too large and become trapped between two filter fiber. Impact is relatively large particles greater cannot follow the curved streamlines in fiber around and, due to the momentum, travel in a straight line into the filter fiber and stick. Interception occurs when the particle "into" runs filter fiber. Diffusion capture occurs when the particles to streamline the activities of molecules of any collision and the surrounding and collision fiber, they re adhesion.
The leak test
ISO 14644-2 of cleanroom test frequency according to cleanroom classification. The test part including leak testing of HEPA filter. ISO 14644-3 general test process and then came.
Equipment requirements
Wet agent generator: used to produce wet agent upstream.of HEPA filter. Particle stability test wet agent has the following issues:
More than 20% by the particle mass less than 0.5.M
More than 50% by the particle mass less than 0.7.M
More than 75% composed of a large number of particles less than 1.M
An annual testing should be performed to verify, wet agent met this issue.
Photometer: used to measure the HEPA filter in the upstream and downstream wet agent content of penetration by the wet agent; it should be calibrated to teenage years.
Particle concentration downstream HEPA filter inverse: used to measure the size of particles of different; it should be calibrated to teenage years.
Figure 1: amplification of the X500 filter media
Figure 2: filter mechanism at work
Wet agent send electrical products testing
Wet agent generator product testing, verification, performed by supplier from year to year, wet agent generator that can cause a stable release. Photometer is checked, sensor/optics and flow rate is within the tolerances. Some of the new digital photometer in the market now have the ability to verify in the "power up" sensor/optics conditions and velocity as the self diagnosis part programming and improved continuously, therefore, the unit reliability rather than annual as calibration and hope it through. Photometer is free in the luminosity of sensor/optics around the meter operator can meet from pollution, flow path is smooth, the unit performed correctly, and the result is correct.
Test method
A linear photometer may be used in the measurement of the upstream concentration provided it is calibrated.
This concentration may be used as reference in the upper reaches 100%, the percentage of penetration is directly measured downstream. Linear photometer may be used to test the filter to 0.01%.
Testing requirements
Each filter requirements for 20 – 100 in the upstream.G/L challenge for best results. You must find the filter and air flow through the filter before the production range calculation filter. Production of products and must give the wet agent products must. Alternatively, the wet agent may be adjusted reference photometer at 100%.
Test process
Dispersion test wet agent upstream.of HEPA filter leads to a consistent challenge is concentrated in this area 20 - 100.G/L. Using a photometer, measurement in the upstream challenge concentration.
To maintain this concentration during the test. Adjusting wet agent generator such challenges, concentrated in the upstream of the filter face is at the level of this spectrometer can be set and maintained in a stable reading 100%. The photometer is then set to 100%.
Use the same spectrophotometer, scanning the downstream face and perimeter all contained seal hunting equipment to sampling probe. With a probe about 25 mm from the regional test and through the entire region of overlap in a stroke, at a rate of 5 cm/sec. Record any photometric stable, repetitive reading place beyond 0.01% for grades A to D in the clean environment related group. See ISO 14644-3 B.6.2.5 for a more specific practices.
Guide
Should be take care when caused by upstream of the wet agent as many wet agent will focus on filter and filter replacement will be necessary; use too little moisture agent and there might be a lack of adequate moisture agent effectively scanning filter. Talking about the plot and reached an agreement on the upstream concentration.
Once the leak has been detected, the filter repairs will be necessary, in the manufacturer ’s practices regarding repair form of media and guide after re sealed filter and perform the test in repair. In the successful test, particle counter placed evaluation of filter in filter, can be used as a backup to the photometer.
The HEPA filter cooperation, consultation Li Gong 15914315027, soul purification, quality of the world